EICR Testing for Landlords: What London Property Owners Need to Know

If you own or manage rental property in London, an EICR is not optional paperwork you can put off. It is a legal requirement, and getting it wrong can mean fines or difficulty renting the property out at all. Here is what it actually involves and what you need to do to stay compliant.

EICR testing guide for landlords and property owners in London

What an EICR Actually Is

An Electrical Installation Condition Report, or EICR, is produced after a qualified electrician inspects the fixed wiring, consumer unit, sockets, and other permanent electrical installations in a property. It is not the same as testing individual appliances, which falls under PAT testing instead. An EICR looks at the building’s electrical infrastructure itself.

Why London Landlords Need One

London’s rental stock includes a huge range of building ages, from Victorian conversions to new-build flats, and electrical installations degrade over time regardless of how new or old the building looks on the surface. An EICR identifies faults such as damaged wiring, overloaded circuits, and outdated components before they cause a fire or an electric shock.

The Legal Requirement Behind EICR Testing

Under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, landlords must have the electrical installations in their rental properties inspected and tested by a qualified person at least every five years. This applies to all specified tenancies in England, and the regulations were extended in 2025 to cover the social rented sector as well.

Official GOV.UK guidance confirms that landlords must give tenants a copy of the report, and provide it to the local housing authority within seven days if requested.

What Happens During an EICR Inspection

An electrician checks the condition of wiring, sockets, switches, the consumer unit, and earthing and bonding arrangements throughout the property. Each issue found is given a classification, from urgent safety risks that need immediate attention to minor observations that are worth noting but not dangerous. The final report gives the installation an overall pass or fail rating.

What Happens If a Property Fails

A fail rating does not mean the property cannot be rented at all, but it does mean the landlord must act. Any urgent or potentially dangerous issues need to be fixed, usually within 28 days, and the landlord must provide written confirmation that the work has been completed. Ignoring a fail rating leaves landlords exposed to fines and, in the event of an incident, questions about why known issues were not addressed.

How This Fits With Other Landlord Duties

EICR testing sits alongside other checks landlords are expected to keep on top of, including gas safety certificates, smoke and carbon monoxide alarms, and where relevant, fire risk assessments for shared parts of the building. Treating these as a single ongoing compliance routine, rather than separate one-off jobs, makes it far easier to stay on the right side of the law.

Common Mistakes London Landlords Make

One of the most frequent mistakes is assuming a property is exempt because it is newly built or recently renovated. New wiring can still develop faults, and the five year rule applies regardless of the property’s age. Another common mistake is leaving the EICR until a tenancy renewal is already underway, which leaves little time to arrange remedial work if issues are found. Booking the inspection with enough lead time avoids this pressure and gives you room to deal with any problems properly rather than rushing repairs to meet a deadline.

Some landlords also assume that because a previous EICR passed, the property will always pass again. Wear and tear, tenant behaviour, and any electrical work carried out between inspections can all affect the result, which is exactly why the five year retest requirement exists rather than a one-off check.

If you already manage PAT testing for appliances in your rental properties, our guide on what PAT testing is and why it matters explains how it differs from an EICR and where the two overlap.

Pro Fire Safe carries out landlord EICR testing in London, with clear reports and support if any remedial work is needed to bring a property up to standard.

Frequently Asked Questions

An EICR, or Electrical Installation Condition Report, is a report produced after a qualified electrician inspects and tests the fixed electrical installations in a property to check they are safe.
Landlords in England must have the electrical installations in their rental properties inspected and tested at least every five years under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020.
If a property fails its EICR, the landlord must carry out any remedial or investigative work identified within 28 days, or sooner if the report specifies a shorter timeframe, and provide written confirmation once the work is complete.