Fire Door Testing Checklist for Landlords and Property Managers

Fire doors protect escape routes and slow the spread of smoke during a fire.

For landlords and property managers in London, regular checks are essential.

This simple checklist will help you spot common problems early, understand your duties and decide when to arrange fire door testing in London for your property.

Fire Door Testing Checklist for Landlords and Property Manager

Why Landlords Must Check Fire Doors Regularly

Fire doors are required in shared buildings, HMOs and many rented properties. When they fail, smoke can move through stairwells and hallways quickly.

Landlords and managing agents have a legal duty to keep fire doors in safe working order. You can read more about these duties on the official GOV.UK fire safety guidance.

Fire Door Testing Checklist

Use this list during monthly visual checks and formal inspections.

1. Check the Door Closes Properly

The door must close on its own from any open point. Look for:

  • Door sticking or dragging
  • Door bouncing off the frame
  • Door not latching fully

If the door does not close smoothly, book a test.

2. Look for Gaps Around the Door

Gaps should be even and within safe limits.

Warning signs:

  • Large gaps at the top or sides
  • Light visible around the frame
  • Gaps changing when the door moves

If unsure, arrange a full inspection.

3. Inspect Seals and Strips

Smoke and intumescent seals should be:

  • Intact
  • Fitted securely
  • Free from cracks
  • Continuous around the frame

Loose or damaged seals fail during a fire.

4. Check Hinges and Fixings

Fire door hinges must:

  • Have the correct number of screws
  • Be tight and secure
  • Show no rust or cracking

Worn hinges affect how the door closes.

5. Inspect the Door Surface and Edges

Look for:

  • Holes
  • Deep scratches
  • Cracks in glazing
  • Loose panels

Any damage can weaken the door.

6. Make Sure Fire Door Signs Are Correct

Doors should have clear signs such as:

  • “Fire Door Keep Shut”
  • “Fire Door Keep Locked”

Missing signs are a common failure during fire door testing.

7. Check That the Door Is Not Wedged Open

Fire doors must remain closed unless fitted with approved hold-open devices linked to the fire alarm.

If the door is regularly wedged open, an engineer should assess the cause.

When to Arrange Professional Fire Door Testing

Landlords should book a test:

  • Every six months for most buildings
  • Every three months for HMOs or busy properties
  • After any reported damage
  • After refurbishment or building work

If faults are found, arrange repairs through fire door maintenance.

If the property has shared corridors or stairwells, consider a full communal fire risk assessment to support wider safety checks.

Fire Door Testing FAQs

A trained and competent fire door inspector should perform formal tests. They check alignment, gaps, seals and overall condition.
Yes. Landlords and managing agents must check fire doors in shared areas and keep records of inspections.
Busy HMOs benefit from formal checks every three to six months, depending on wear and use.

Final Thoughts

A simple checklist helps keep fire doors in safe condition and supports legal duties. Regular checks give early warning of faults and help avoid more serious problems.