Fire Risk Assessments for Care Homes: What the Law Requires in London

A care home presents fire safety challenges that are found in no other type of building. The people inside it are among the most vulnerable in any fire emergency. Many cannot self-evacuate. Some cannot understand or respond to an alarm. Others are connected to medical equipment that itself introduces fire risk. Staff are present around the clock, but shift patterns mean the number of people available to assist an evacuation at 3am may be very different from midday.

For these reasons, fire risk assessments for care homes carry a greater weight of legal obligation, and a greater level of enforcement scrutiny, than assessments for almost any other premises type in London.

This guide explains what the law requires, what makes a care home fire risk assessment different from other buildings, what the CQC looks for, and where compliance most commonly breaks down.

Fire risk assessor reviewing evacuation plans and fire safety documentation inside a London care home

Why Care Homes Are Treated Differently Under Fire Safety Law

The Regulatory Reform (Fire Safety) Order 2005 applies to all care homes in the same way it applies to any other non-domestic premises. The responsible person must carry out and maintain a suitable and sufficient fire risk assessment, implement appropriate fire safety measures, and record everything in writing.

But the specific guidance for care homes, set out in the government’s fire safety risk assessment guide for residential care premises, recognises that a standard commercial risk assessment is not adequate for a building where residents may require staff assistance to reach safety. The assessment must go significantly further.

The core distinction is this: in most buildings, the fire safety strategy assumes that occupants can hear an alarm and leave under their own power. In a care home, that assumption cannot be made. The fire risk assessment must be built around the actual capabilities of every person in the building, and the evacuation plan must work even for residents who cannot walk, cannot follow instructions, or are asleep and sedated.

Key legislation for care home fire safety in London

  • Regulatory Reform (Fire Safety) Order 2005 (RR(FS)O)
  • Fire Safety Act 2021
  • Fire Safety (England) Regulations 2022
  • Building Safety Act 2022 (Section 156 — written records mandatory for all)
  • Health and Social Care Act 2008 (Regulated Activities) Regulations 2014 — Regulation 12
  • BS 9991:2024 — fire safety in design, management and use of residential buildings, now extended to residential care homes
  • Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 — PEEPs, in force from April 2026

The Enforcement Picture: Why Care Homes Are Under Intense Scrutiny

Care homes are one of the most intensively audited premises types by fire and rescue services across England, and enforcement action is consistently high.

According to the Government’s fire prevention and protection statistics for the year ending March 2025, care homes received 192 enforcement notices in 2024/25, accounting for 11% of all enforcement notices issued across England. Only shops received more. This pattern was consistent in the previous year, with care homes again recording the second-highest volume of any premises type.

The consequences of non-compliance are serious. In one documented London-area case, Morven Healthacre Ltd was fined £45,000 plus £23,000 in costs at Croydon Crown Court for five offences under the RR(FS)O at a Kenley care home, including blocked fire exits, an out-of-date risk assessment, inadequate fire detection, and no emergency plan. In another case, a care home owner in Knutsford received a 12-month suspended sentence and 200 hours’ community service for fire safety offences.

In London, the London Fire Brigade enforces the RR(FS)O independently of the CQC, and both bodies can take action at the same time. A care home that receives an enforcement notice from the London Fire Brigade may simultaneously face CQC concerns about safe care and treatment. The two regulatory regimes overlap but do not replace each other.

What the Law Requires: The Five Core Duties

1. A Suitable and Sufficient Written Fire Risk Assessment

The responsible person must carry out a fire risk assessment that is specific to the care home’s building, layout, occupancy, and resident population. A generic template or an assessment produced for a different building is not adequate. The assessment must identify every fire hazard present, evaluate the risk level, and set out what measures are in place and what further action is required.

Since Section 156 of the Building Safety Act 2022 came into force, this assessment must be recorded in writing for all premises covered by the RR(FS)O. There is no longer any size threshold below which a written record is optional. For a care home, this has always been the expectation in practice, but it is now a hard legal requirement with no exceptions.

2. Personal Emergency Evacuation Plans for Every Resident Who Needs One

A Personal Emergency Evacuation Plan, or PEEP, is a written document that sets out exactly how a specific individual will be evacuated from the building in the event of a fire. It records their mobility, cognitive ability, and any medical needs that affect how they move, where they sleep, and how staff will assist them.

PEEPs must be in place for every resident who cannot self-evacuate. In a residential care home, this is likely to be the majority of residents. Each PEEP must be reviewed when a resident’s condition changes, when they move to a different room, and at least annually.

From April 2026, the Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 formalise the duty on responsible persons to identify residents who may need evacuation assistance and to agree written PEEPs with those who request them. Care homes that do not already have PEEPs in place for all relevant residents are operating below the expected legal standard now, and will be in clear breach once the Regulations are fully in force.

3. A Progressive Horizontal Evacuation Strategy

Standard buildings use a simultaneous evacuation strategy: everybody hears the alarm and leaves at the same time. This is not appropriate for most care homes, where moving all residents simultaneously through stairwells is neither safe nor achievable.

Instead, care homes typically use progressive horizontal evacuation. This moves residents from the zone of fire origin to an adjacent fire-compartmented zone on the same floor. Residents remain in place until a full evacuation is necessary, buying time for staff to assist those who need it most.

Your fire risk assessment must confirm that the building’s compartmentation is adequate to support this strategy, that staff understand the procedure and have practised it, and that the means of escape for each zone is clearly defined and unobstructed at all times.

4. Staff Fire Safety Training and Regular Drills

The fire risk assessment must identify the training needs of all staff. In a care home, this goes beyond basic fire warden training. Every member of staff must understand the evacuation procedures for their floor or area, know how to assist residents with varying levels of dependency, and be familiar with the location of all fire exits, fire fighting equipment, and the fire alarm panel.

Fire drills must be carried out regularly, including during night shifts, since nighttime staffing levels are typically much lower and the evacuation challenge is greater. Each drill must be recorded, including any problems identified and how they were addressed.

The CQC checks training records during inspection. Gaps in training, or a lack of drill records, are among the most common reasons care homes receive fire safety-related concerns during CQC visits.

5. Maintenance of All Fire Safety Systems and Equipment

The fire risk assessment must be supported by a functioning programme of maintenance for all fire safety systems. In a care home this includes:

  • Fire detection and alarm systems, which must be tested weekly and serviced at minimum every six months to BS 5839
  • Emergency lighting, tested monthly and serviced annually to BS 5266
  • Fire doors throughout the building, checked regularly for condition, gaps, self-closing function, and integrity of seals
  • Fire extinguishers, serviced annually to BS 5306
  • Sprinkler systems where installed, maintained to BS EN 12845

Maintenance records must be kept and made available to the London Fire Brigade or CQC on request. An absence of records is treated the same as an absence of maintenance.

Specific Fire Risks in Care Homes That the Assessment Must Address

A care home fire risk assessment must go beyond the standard list of ignition sources and fuel loads. The following risks are specific to the care environment and must be explicitly assessed.

Medical Equipment and Oxygen Therapy

Oxygen concentrators and cylinders are present in many care home rooms. Oxygen-enriched environments dramatically accelerate fire spread and increase burn severity. Rooms where oxygen is in use require specific risk controls, including designated storage areas for oxygen equipment, no-smoking policies that are actively enforced around those rooms, and specific guidance in the relevant residents’ PEEPs.

Powered wheelchairs, electric adjustable beds, pressure-relief mattresses, and battery-powered medical devices all introduce additional ignition risks, particularly during overnight charging. The assessment must identify where these items are charged and whether the electrical load and storage arrangements are safe.

Smoking by Residents

Smoking remains a significant ignition source in care homes. The London Fire Brigade’s own guidance notes that a substantial proportion of care home fires involve smokers’ materials. Residents who smoke must have designated, supervised smoking areas, and the risks associated with smoking alongside oxygen therapy or emollient skin products must be specifically assessed and controlled.

Kitchen and Laundry Areas

Commercial catering kitchens and industrial laundry equipment both present elevated fire risks. The assessment must confirm that kitchen extraction systems are cleaned regularly to prevent fat build-up, that cooking equipment is serviced, and that laundry dryers are not left running unattended overnight.

Resident Bedrooms

In a care home, resident bedrooms are the highest-risk area for fire origin. Personal electrical items, smoking materials, emollient products, and medical equipment can all combine in a single room. The assessment must address how bedroom door fire resistance is maintained, how room contents are managed, and how staff monitor bedrooms during the night.

Night Shift Staffing Levels

The evacuation capability of a care home at 2am is very different from 10am. Your fire risk assessment must reflect the worst-case evacuation scenario, which typically occurs during the night shift. If the assessment assumes daytime staffing levels, it does not accurately describe the risk. Staff numbers on each shift must be sufficient to carry out the progressive horizontal evacuation plan for all residents who need assistance.

The CQC's Role: How Fire Safety Sits Within Regulation 12

The Care Quality Commission is not a fire safety enforcer in the same way as the London Fire Brigade, but fire safety is embedded within its inspection framework under Regulation 12 of the Health and Social Care Act 2008 (Regulated Activities) Regulations 2014, which covers safe care and treatment.

During inspections, CQC inspectors look for:

  • A current, written fire risk assessment that is specific to the premises
  • PEEPs in place for all residents who require evacuation assistance
  • Fire drill records, including night-time drills
  • Staff training records confirming all staff have received fire safety training
  • Maintenance records for fire detection, emergency lighting, and fire doors
  • Evidence that fire safety is embedded in day-to-day management, not just compliance documents

A CQC inspection that identifies fire safety failures may lead to a formal requirement for improvement, a restriction on new admissions, or referral to the London Fire Brigade for enforcement. In serious cases, the CQC can cancel a care home’s registration, which closes the service entirely.

New Requirements Introduced Since 2022

The regulatory framework for care home fire safety has changed substantially in recent years. If your fire risk assessment was produced before 2022, it is almost certainly out of date and needs to be reviewed in full.

ChangeWhat It Means for Care HomesIn Force From
Building Safety Act 2022 — Section 156Written fire risk assessment compulsory for all premises, no size exceptionsOctober 2023
Fire Safety (England) Regulations 2022Quarterly fire door checks on communal doors; annual checks on flat/room entrance doorsJanuary 2023
BS 9991:2024Extended to cover residential care homes; updated evacuation strategy and sprinkler guidanceNovember 2024
Mandatory sprinklers in new care homesAll new care homes must install sprinkler systems regardless of building heightMarch 2025
Fire Safety (Residential Evacuation Plans) Regulations 2025Formal duty to identify residents needing evacuation assistance and agree written PEEPsApril 2026

What a Fire Risk Assessment for a London Care Home Should Include

A suitable and sufficient fire risk assessment for a care home in London will cover all of the following as a minimum:

  • Full identification of ignition sources, fuel loads, and oxygen sources across the building
  • Assessment of fire detection and alarm provision against BS 5839, including coverage in all resident rooms and communal areas
  • Review of fire compartmentation throughout the building, including all fire doors, floor and wall penetrations, and ceiling voids
  • Assessment of means of escape from every part of the building, including bedrooms, communal rooms, and kitchen and service areas
  • Review of emergency lighting provision against BS 5266
  • Assessment of all fire fighting equipment
  • Resident dependency assessment identifying all individuals who require evacuation assistance
  • Review of PEEPs for all relevant residents
  • Assessment of progressive horizontal evacuation strategy and its adequacy for current occupancy
  • Review of staff training records and fire drill records
  • Assessment of night-shift staffing against evacuation requirements
  • Review of smoking policy and its implementation
  • Assessment of medical equipment storage and charging arrangements
  • Prioritised action plan with risk ratings for each finding

The written report must be kept on file and made available to the London Fire Brigade, the CQC, and your insurer on request.

For more on what a full fire safety assessment covers across different building types, see our fire risk assessment services in London page.

How Often Must a Care Home Fire Risk Assessment Be Reviewed?

Annual review is the standard minimum expectation for care homes. But the nature of a care home means that review triggers arise more frequently than in most other buildings.

The assessment must be reviewed whenever:

  • There is a structural change to the building
  • There is a significant change in the resident population or their dependency levels
  • A resident is admitted with specific medical needs that affect fire risk, such as regular oxygen therapy
  • Staffing arrangements change significantly, particularly overnight staffing levels
  • A fire or near miss occurs on the premises
  • New fire safety legislation comes into force that affects the building
  • Maintenance inspections identify problems with fire safety systems

In practice, many London care homes review fire safety documentation more frequently than once a year, because the resident population and their needs change continuously.

Common Compliance Failures in London Care Home Inspections

The enforcement pattern in London care homes consistently identifies the same categories of failure. The most common are:

Out-of-Date or Absent Fire Risk Assessment

The single most common enforcement trigger is a fire risk assessment that does not reflect the current state of the building or the current resident population. An assessment produced several years ago, filed and never reviewed, will not be considered suitable and sufficient by either the London Fire Brigade or the CQC.

Missing or Inadequate PEEPs

PEEPs that have not been reviewed since a resident’s condition changed, PEEPs that are too generic to be actionable, or no PEEPs at all for residents with mobility impairments are consistently found during inspections. Each PEEP must be resident-specific and must reflect their current needs.

Fire Doors Not Fit for Purpose

In care homes, fire doors are kept shut by self-closers and must never be propped open. Doors that have been wedged open for convenience, doors with damaged seals or gaps that exceed 3mm, and doors where the self-closer has been removed or disabled all compromise compartmentation. Our fire door assessment service covers all of these checks for care homes and other premises.

No Night-Time Drill Records

Drills that only happen during the day do not test the actual worst-case evacuation scenario. The London Fire Brigade expects to see drill records across different times of day and night, and will question a care home that cannot demonstrate night-time evacuation practice.

Blocked Escape Routes

Equipment stored in corridors, wheelchairs parked in front of fire exits, and locked fire doors that should remain accessible are found regularly during inspections. Escape routes must be clear and accessible at all times, not just during the day shift.

Need a fire risk assessment for a care home in London?

Pro Fire Safe provides fire risk assessments for care homes and other regulated premises across London. Our assessments are specific to your building and resident population, and cover all requirements under the RR(FS)O 2005 and current CQC expectations. Contact us on 0207 205 7337 or email admin@profiresafe.co.uk.

Frequently Asked Questions

Yes. Under the Regulatory Reform (Fire Safety) Order 2005, the responsible person for a care home must carry out and maintain a suitable and sufficient fire risk assessment. This applies to all residential care premises in London, including nursing homes, dementia care homes, and supported living properties with staff on duty. The assessment must be recorded in writing under Section 156 of the Building Safety Act 2022, regardless of the size of the premises.
The responsible person is typically the registered provider or the registered manager named on the CQC registration. They are legally required to carry out a fire risk assessment, act on its findings, keep it up to date, and maintain records of all fire safety measures, training, and testing. In large care groups, the responsible person may be the regional director or another senior person with day-to-day control of the premises.
Care home fire risk assessments must address the specific vulnerabilities of the resident population. This includes Personal Emergency Evacuation Plans (PEEPs) for every resident who cannot self-evacuate, a progressive horizontal evacuation strategy suited to residents who cannot use stairs, the fire risks associated with medical equipment including oxygen therapy, the management of smoking by residents, and staff shift patterns and their impact on evacuation capability at all hours of the day and night.
Yes. The CQC assesses fire safety as part of its inspection of care homes under Regulation 12 of the Health and Social Care Act 2008 (Regulated Activities) Regulations 2014, which covers safe care and treatment. Inspectors check whether a current fire risk assessment is in place, whether PEEPs are documented for all relevant residents, and whether staff training and fire drill records are maintained. The London Fire Brigade enforces the RR(FS)O separately and independently of the CQC.
A Personal Emergency Evacuation Plan (PEEP) is an individual written plan setting out exactly how a specific resident will be evacuated in the event of a fire, taking into account their mobility, cognitive ability, and medical needs. From April 2026, the Fire Safety (Residential Evacuation Plans) (England) Regulations 2025 require duty holders in residential buildings, including care homes, to identify residents who may need assistance and agree written PEEPs with those who request them. CQC inspectors have expected PEEPs for care home residents as part of safe care obligations for several years.

Annual review is the standard expectation for care homes. The assessment must also be reviewed after any structural changes to the building, after a significant change in the resident population or their dependency levels, following a fire or near miss, after new staff fire safety procedures are introduced, and whenever new fire safety legislation comes into force. Given that the resident population of a care home changes continuously, reviews are often needed more frequently than in other premises types.