Greenwich is one of the most commercially active boroughs in south-east London. New businesses are opening across Woolwich town centre, Greenwich town centre, Charlton, and Eltham. Existing businesses are refitting their premises, taking on additional space, or welcoming new members of staff. All of that activity is good for the borough. But a lot of it also creates a legal obligation that many business owners overlook: the need to review their fire safety assessment.
The law does not simply require you to have a fire safety assessment. It requires you to keep it up to date. An assessment carried out two years ago on a premises that has since been refurbished, re-tenanted, or significantly altered is no longer legally valid. It does not protect you, and it does not protect the people in your building.
This article explains when Greenwich businesses are required to review their fire safety assessment, what specific triggers apply, and why the commercial property landscape in Greenwich makes regular review particularly important.
The Legal Starting Point: What the RR(FS)O Requires
Under Article 9 of the Regulatory Reform (Fire Safety) Order 2005, the responsible person must not only carry out a fire risk assessment but also review it regularly and make any changes identified as necessary.
The legislation does not set a fixed review interval in months or years. Instead, it requires that the assessment remains “suitable and sufficient” at all times. In practice, this is interpreted as follows:
- Annual review is recognised as the standard minimum for most commercial premises
- Review is required whenever a significant change takes place that could affect fire risk
- Review is required after a fire, explosion, or near miss in the building
Since the Building Safety Act 2022, every fire risk assessment must also be recorded in writing, regardless of the size of the building. There is no longer a threshold below which a written record is optional. That written record must be kept current.
Annual Review: The Minimum Expectation for Greenwich Businesses
For most businesses in Greenwich, reviewing the fire safety assessment once a year is the appropriate starting point. This gives you a regular opportunity to check that nothing has changed in the building, the occupancy, the fire safety equipment, or the relevant legislation that could make your current assessment inaccurate.
An annual review does not always mean a full reassessment. If nothing significant has changed, a documented check confirming the assessment still reflects the current condition of the premises may be enough. But that check must still happen, and it must be recorded.
Where things have changed, even in ways that might seem minor, such as installing a new kitchen, partitioning off a back-office area, or taking on a new member of staff who has specific fire safety responsibilities, the assessment should be updated to reflect those changes.
When Does a Review Become Immediately Required?
Beyond the annual cycle, certain events create an immediate obligation to review your fire safety assessment. These triggers apply to any premises covered by the RR(FS)O, which includes virtually all commercial and shared residential buildings in Greenwich.
Refurbishment and Structural Changes
Trigger: Building works or layout changes
Any change to the physical structure of your premises can alter fire risk. Review your assessment before work begins and again once it is complete.
Greenwich is seeing significant refurbishment activity. Demand for commercial space in the borough is rising, and property data from Hindwoods and Rightmove confirms that demand for retail space in areas including Greenwich is growing, with the number of businesses wanting to lease retail space in the area up 10% on 2024 figures. Many of those new tenants are fitting out or refurbishing units before opening.
Any building work that affects the layout of a premises can invalidate your existing fire safety assessment. This includes:
- Installing or removing internal partitions that affect escape routes or compartmentation
- Adding or relocating a kitchen or cooking area
- Converting storage areas into staff or customer spaces
- Installing new electrical systems or high-load equipment
- Any work that creates penetrations through fire-rated walls, floors or ceilings
- Extending the premises or adding a mezzanine level
Refurbishment work often also reveals pre-existing fire safety problems. Gaps in fire-rated walls where services pass through, deteriorated compartmentation behind plasterboard, or fire doors that were not properly fitted to begin with can all come to light during a fit-out. Arranging a fire safety assessment review after works are complete lets you catch and resolve these issues before the premises opens or re-opens.
Change of Occupancy or Business Use
Trigger: New tenant, new business type, or change of use
A different occupant or a different business activity changes the fire risk profile of the building. The existing assessment may no longer apply.
Greenwich town centre, Woolwich high street, and the streets around Greenwich Market are all seeing active lettings activity as new businesses take over from previous occupants. Each time a unit changes hands, the fire risk picture can change significantly.
Consider a ground-floor unit that was previously a clothes retailer and is now a restaurant. The new occupant introduces open cooking as a heat source, brings in extraction systems, oils, and greater volumes of combustible material, and operates later into the evening with different patterns of staff and customer movement. The fire risk is completely different from the previous use, and an assessment carried out for the retail use has no relevance to the restaurant.
The same applies in less dramatic situations. A change from a low-occupancy back-office use to a customer-facing retail space changes escape requirements. A business that expands to employ significantly more people changes the demands placed on means of escape. Any of these shifts requires a fresh look at the assessment.
Increase in Occupancy or Public Access
Trigger: More people using the building
A significant rise in the number of staff, customers, or visitors changes the demands placed on escape routes and fire safety measures.
Greenwich’s hospitality, retail and events sectors all experience busy periods where occupancy rises sharply above normal levels. Greenwich Market, the town centre and Woolwich Arsenal see particular spikes at weekends, during tourist season, and over Christmas. If your premises regularly fills to a higher occupancy than your current fire safety assessment assumes, the escape strategy in that document may not be adequate.
This is also relevant to businesses that have grown since their last assessment. A business that started with three staff and now employs fifteen needs to check that its assessment still accounts for the correct number of people, the correct emergency procedures, and an appropriate level of staff fire safety training.
After a Fire, Explosion, or Near Miss
Trigger: A fire incident or near miss on the premises
Any fire or near miss is an indication that something in the existing assessment did not work as expected. A full review is essential before normal occupation resumes.
If a fire, even a contained one, or a serious near miss takes place at your premises, your existing fire safety assessment must be reviewed immediately. The incident may have revealed hazards or failures in your fire safety measures that the previous assessment did not identify or adequately address. Operating from an unchanged assessment after a known incident leaves you legally exposed and increases the risk of a repeat event.
Changes to Fire Safety Legislation
Trigger: New laws or updated guidance affecting your building type
Changes to fire safety legislation can alter what your assessment must cover. Check that your current document reflects the latest legal requirements.
Recent years have brought significant changes to fire safety law. The Fire Safety Act 2021, the Fire Safety (England) Regulations 2022, and the Building Safety Act 2022 all introduced new duties that affect how fire safety assessments must be carried out and recorded for certain building types. If your assessment was produced before any of these changes came into force, it may not meet current requirements.
Greenwich-Specific Risks That Make Regular Review More Important
A Fast-Moving Commercial Lettings Market
The volume of new lettings, especially in Woolwich, Greenwich town centre, and around Greenwich Peninsula, means that many buildings are changing occupants and use more frequently than in slower markets. Each change is a review trigger. Freeholders and managing agents who do not have a process in place for updating the fire safety assessment at each re-letting are accumulating compliance risk.
Older Building Stock
Large parts of the Greenwich borough contain Victorian and Edwardian commercial stock, converted buildings, and older purpose-built residential blocks. These buildings were not designed with modern fire safety standards in mind. Compartmentation can degrade silently between reviews. Fire doors fitted years ago may have deteriorated. Emergency lighting systems may not have been serviced to BS 5266 requirements. In older stock especially, annual review is not just a legal formality. It is the primary way of catching problems before they lead to enforcement action or, more seriously, a fire that causes harm.
Mixed-Use Premises
Many commercial units in Greenwich sit beneath or alongside residential properties. In these buildings, the responsible person for the commercial part of the building and the responsible person for the residential common areas may be different parties. Both must maintain current fire safety assessments for their respective areas. Changes to either part of the building, including new residential tenants moving in above a commercial unit, can affect the overall fire risk picture and may require both parties to review their assessments.
Hospitality and Food and Beverage Premises
Greenwich has a strong and growing food and beverage sector, particularly around Greenwich Market, the waterfront, and the high street. Restaurants, cafes, takeaways and bars present a higher fire risk than many other commercial premises because of cooking equipment, accelerants, and extended operating hours. These premises typically require more frequent review and closer attention to fire safety measures, particularly around kitchen suppression, means of escape for late-night occupancy, and fire door maintenance.
A Quick Reference: Review Triggers for Greenwich Businesses
| Trigger Event | Review Required? | Timing |
|---|---|---|
| 12 months since last review | Yes | At the 12-month point |
| Refurbishment or structural changes | Yes | Before work starts and after completion |
| New tenant or change of business use | Yes | Before new occupant takes possession |
| Significant increase in staff or public access | Yes | Before the increase takes effect |
| Fire, explosion, or near miss on premises | Yes | Immediately after the incident |
| New fire safety legislation relevant to building type | Yes | As soon as legislation comes into force |
| Change in fire safety equipment or layout | Yes | At the time of the change |
| Complaint or concern raised by employee or tenant | Advisable | As soon as concern is raised |
What Does a Fire Safety Assessment Review Involve?
A review is not simply a re-reading of the old document. It is a fresh evaluation of the premises to check whether the findings, risk ratings and actions in the existing assessment still accurately describe the building and its risks.
A thorough review covers:
- Walking the premises to identify any changes since the previous assessment
- Checking that fire detection, alarm systems, and emergency lighting are functioning and serviced
- Inspecting fire doors for condition, gap tolerances, and self-closing function
- Confirming that escape routes are clear, signed, and adequate for current occupancy
- Checking that fire extinguishers are present, correctly positioned, and in date
- Reviewing maintenance records and any outstanding actions from the previous assessment
- Confirming that staff fire safety training and procedures are current
The outcome of the review must be recorded in your written fire safety assessment. Any new hazards found, any changes to risk ratings, and any new actions required must all be documented.
For more on what a full fire safety assessment service covers, see our fire risk assessment services in London page.
What Happens If You Do Not Review Your Assessment?
Operating from an out-of-date fire safety assessment is a breach of the Regulatory Reform (Fire Safety) Order 2005. The consequences can be serious.
According to Government fire prevention and protection statistics for the year ending March 2025, fire safety audits across England resulted in 2,972 formal enforcement notifications, an increase of 29% compared with five years earlier. The London Fire Brigade is one of the most active enforcement authorities in the country, and Greenwich businesses are within its jurisdiction.
Enforcement outcomes include:
- Enforcement notices requiring specific improvements within a defined timescale
- Prohibition orders preventing use of part or all of your premises until issues are resolved
- Unlimited fines on conviction in the Magistrates’ or Crown Court
- Prosecution of individuals, not just the business entity, in serious cases
Beyond the legal risk, an out-of-date assessment leaves people in your building genuinely less safe. The whole point of keeping it current is that it reflects real risk, not a snapshot from years ago that no longer describes the building you are responsible for.
Common Reasons Greenwich Businesses Fall Behind on Reviews
In our experience, reviews slip for a small number of predictable reasons. Knowing them helps you avoid them.
No Review Date in the Calendar
The most common reason is simply that nobody set a reminder. The initial assessment was done, filed, and never revisited. Set a recurring annual review date in your business calendar at the point the assessment is completed, and assign a named person to own it.
Assuming the Previous Assessment Covers Recent Changes
It is easy to assume that a refurbishment that felt minor, a new member of staff, or a small extension to the premises does not require a review. In many cases it does. If you are not sure whether a change is significant enough to trigger a review, the safer choice is to check.
Relying on a Contractor to Notify You
Building contractors and fit-out specialists are not fire safety assessors. Their job is to complete the works you have engaged them for. The responsibility for ensuring your fire safety assessment reflects the completed works sits with you as the responsible person.
Change of Ownership or Management Without a Handover
When a business changes hands or a new managing agent takes over a property, fire safety documentation does not always transfer cleanly. New owners and new managing agents should check at the point of handover that a current, written fire safety assessment exists, when it was last reviewed, and what actions remain outstanding.
Our fire safety assessments for commercial properties in London service page covers how we support businesses and managing agents through this process.
Need to review your fire safety assessment in Greenwich?
Pro Fire Safe carries out fire safety assessment reviews for businesses, landlords and managing agents across London. Contact us on 0207 205 7337 or email admin@profiresafe.co.uk to arrange a review at your Greenwich premises.
Frequently Asked Questions
How often should a fire safety assessment be reviewed in Greenwich?
Annual review is the standard best practice for all businesses in Greenwich. Beyond that, you must also review your fire safety assessment after any structural changes, change of occupancy or use, following a fire or near miss, after significant changes to the number of people using the building, and whenever new fire safety legislation comes into force. There is no fixed maximum interval set in law, but an assessment that has not been reviewed within 12 months may no longer be considered suitable and sufficient.
Does refurbishment trigger a fire safety assessment review?
Yes. Any structural or layout change to your building can alter fire risk, affect compartmentation, or change escape routes. This makes your existing assessment out of date. You should arrange a review before refurbishment work begins where possible, and again once the work is complete.
If a new tenant takes over a unit in Greenwich, does the fire safety assessment need updating?
Yes. A change of tenant or change of use changes the occupancy profile of the building. A cafe replacing an office, for example, introduces cooking as a new ignition source, changes opening hours, and brings in a different pattern of public access. These changes affect fire risk and must be reflected in a fresh assessment.
What happens if a business in Greenwich has an outdated fire safety assessment?
An outdated assessment does not meet the legal requirement for a suitable and sufficient fire risk assessment under the Regulatory Reform (Fire Safety) Order 2005. The London Fire Brigade and Greenwich Council can issue enforcement notices or prohibition orders. In serious cases, prosecution and unlimited fines can follow. An outdated assessment also provides no legal protection if a fire occurs.
Does a seasonal business in Greenwich need to review its fire safety assessment more often?
If your business sees significant variation in the number of people on the premises at different times of year, such as a hospitality venue near Greenwich Market in summer or a retail unit during peak trading periods, you should check that your fire safety assessment accounts for maximum occupancy. If the difference is substantial, a review is advisable.
Who is responsible for reviewing a fire safety assessment in a shared building?
Each responsible person is accountable for their own area. In a shared building, this typically means the business owner or tenant covers their own commercial space, while the freeholder or managing agent covers common areas including corridors, stairwells and shared entrances. Both parties must ensure their assessments are current.