How to Read a Fire Door Report: A Guide for Landlords and Property Managers

Getting a fire door report done is only half the job. The real value comes from understanding what it says and knowing what to do with it. If you have a report sitting in your inbox full of terms like “advisory”, “fail” and “priority level”, this guide breaks it down in plain English.

Fire safety inspector reviewing a fire door report showing pass, advisory and fail ratings

What a Fire Door Report Actually Tells You

A fire door report is a written record of a physical inspection. It tells you the condition of each door, whether it meets current standards, and what needs fixing. Think of it less as a certificate and more as a snapshot of risk, one that gives you a clear list of what is safe, what needs watching, and what needs fixing now.

If you want to understand the difference between the physical check and the paperwork it produces, our post on fire door testing versus fire door surveys covers that distinction in more detail.

Understanding Pass, Advisory and Fail Ratings

Most fire door reports use a three-tier rating system for each item checked. Here is what each one means in practice.

Pass

The item meets the required standard. No action is needed until the next scheduled check.

Advisory

The item is not an immediate risk but is showing early signs of wear, or is close to the edge of what is acceptable. It is worth fixing on your next maintenance visit rather than leaving it to worsen.

Fail

The item does not meet the required standard. The door’s ability to hold back fire or smoke may be compromised, and repair or replacement is needed.

Priority Levels Explained

Alongside the pass, advisory or fail rating, a good fire door report also assigns a priority level. This tells you how quickly to act.

Urgent

The issue directly affects the door’s fire performance right now. This should be actioned as soon as possible, ideally within days.

Advisory (Medium)

The issue should be fixed but does not present an immediate danger. This can usually be scheduled within a few weeks.

Monitored (Low)

A minor observation worth keeping an eye on at future inspections, but not something that needs immediate spend.

Common Findings in London Fire Door Reports

Across the buildings we inspect, a handful of issues come up again and again:

  • Gaps around the door or threshold that fall outside BS 8214 tolerances
  • Missing or damaged intumescent and smoke seals
  • Door closers that do not fully latch the door from an open position
  • Missing or illegible fire door signage
  • Damaged or missing certification labels

Dwelling fires remain the largest single category of fire risk in England. Government figures show that dwelling fires accounted for 72% of all fire-related fatalities in the year ending September 2025. A properly functioning fire door is one of the simplest ways to reduce that risk, which is exactly why the findings in your report matter.

What to Do After You Receive Your Report

Once you have your report, work through it in order of priority rather than trying to fix everything at once.

  1. Deal with any urgent or fail items first, either through your own contractor or the company that produced the report
  2. Schedule advisory items into your next maintenance round
  3. File the report along with photos and any invoices for completed repairs
  4. Set a reminder for your next inspection based on the type of door and how often it is used

Under the Fire Safety (England) Regulations 2022, responsible persons in multi-occupied residential buildings must carry out regular checks on communal fire doors and flat entrance doors that open onto escape routes. A dated report showing you have acted on the findings is exactly the kind of evidence a fire authority will expect to see.

Why Keeping Your Reports on File Matters

A single report is useful on its own, but a full history of reports over several years tells a much stronger story. It shows a pattern of regular checks, prompt repairs, and ongoing care of the building, which is exactly what insurers, fire authorities, and buyers or lenders want to see if a building ever changes hands.

If you are still waiting on your first report, or it has been longer than 12 months since your last one, our team can carry out full fire door reports across your London property and talk you through the findings in person.

Frequently Asked Questions

What does a fail rating on a fire door report mean?

A fail rating means the fire door does not meet the required standard and needs remedial work or replacement before it can be relied on to perform in a fire. The report will set out exactly what caused the fail and how urgent the fix is.

What is the difference between advisory and urgent priority on a fire door report?

Urgent priority means the issue affects the door’s ability to perform in a fire and should be fixed straight away. Advisory priority flags a smaller issue, such as minor wear, that should be addressed but does not present an immediate risk.

Do I need to act on every item in a fire door report?

Yes, in the sense that every item should be reviewed and a plan put in place. Urgent and fail items need prompt action, while advisory and monitored items can usually be scheduled into your regular maintenance programme.

Can I use a fire door report to prove compliance to my insurer?

Yes. A dated, itemised fire door report from a qualified inspector is one of the clearest ways to show an insurer or fire authority that you are meeting your fire safety duties.

How long should I keep old fire door reports?

Keep every report on file for the life of the building, or at minimum several years, so you can show a consistent history of checks and repairs rather than a single snapshot in time.

Need a fire door report you can actually act on? Get in touch with Pro Fire Safe to book a fully documented inspection across your London property.